Pada video ini saya membuat video tentang Cara setting manual protection relay sepam S40 semoga bermanfaat untuk penonton kami. Jika ada pertanyaan mengena. Sepam series 40 offers 13 types of digital current or voltage protection for demanding distribution systems, each one dedicated to a single application. Characteristics: 3 types of User-Machine Interface; 4 current inputs; 3 voltage inputs; 8 relay outputs logic equation editor; 1 Modbus communication port; 16 temperature sensor inputs. Sepam series 40 Contents Presentation 1/2 Selection table 1/3 Electrical characteristics 1/4 Environmental characteristics 1/5 1/1 1 PCRED301006EN1INTRO.FM Page 2 Mercredi, 23. Avril 2003 3:49 15 Sepam series 40 MT10357.

Sepam s40 manualprimofasr timing

Sepam S40 Manual

Manualprimofasr

Sepam S40 Manualprimofasr Timing

Pada video ini saya membuat video tentang Cara setting manual protection relay sepam S40 semoga bermanfaat untuk penonton kami. Jika ada pertanyaan mengena. Sepam series 40 offers 13 types of digital current or voltage protection for demanding distribution systems, each one dedicated to a single application. Characteristics: 3 types of User-Machine Interface; 4 current inputs; 3 voltage inputs; 8 relay outputs logic equation editor; 1 Modbus communication port; 16 temperature sensor inputs. Sepam series 40 Contents Presentation 1/2 Selection table 1/3 Electrical characteristics 1/4 Environmental characteristics 1/5 1/1 1 PCRED301006EN1INTRO.FM Page 2 Mercredi, 23. Avril 2003 3:49 15 Sepam series 40 MT10357.

Sepam S40 Manual

Sepam S40 Manualprimofasr Review

Electrical network protection
Technical data sheet
2008
1
Standard
IEC 61850
Base unit, with various types of User Machine Interfaces (UMI): b basic UMI b advanced UMI with graphical LCD screen.
2
Remote advanced UMI.
3
10 logic inputs and 8 output relays, 4 outputs on the base unit + 1 optional module providing 10 inputs and 4 outputs.
4
Sepam series 40 is a family of current and voltage digital protection relays, for medium voltage public and industrial distribution networks. PE50546
Sepam series 40 and its optional modules
Sepam series 40
1 communication port: b connection to 1 or 2 S-LAN and/or E-LAN networks b Modbus, Modbus TCP/IP, IEC60870-5-103, DNP3 and IEC 61850 communication protocols b RS 485 ( 2or 4 wire) or fiber optic network.
5
Temperature data from 16 sensors, Pt100, Ni100, or Ni120.
6
1 analog output, 0-10mA, 4-20mA or 0-20mA.
7
Software tools: b Sepam parameter and protection setting and control function customization b recovery and display of disturbance recording data b local or remote operation via an E-LAN.
4
3 1
6
5 7 2
Characteristics Conformity to standards IEC 60255 - Protection relays IEC 60529 - Degree of protection
IP52 on front panel
IEC 60068 - Operating temperature
-25°C to +70°C (-13°F to +158°F)
Certifications CE, UL508, CSA C22.2
Auxiliary power supply 24-250 V DC and 110-240 V AC
Overall size of base units (H x W x D) 222 X 176 X 130 mm
Protections
ANSI code
S40
S41
S42
S43
T40
T42
M41 G40
Phase overcurrent
50/51
4
4
4
4
4
4
4
4
b S40, S41, S42, S43: substation incomers and feeders protection b T40, T42: transformer protection b M41: motor protection b G40: generator protection
Voltage restrained overcurrent
50V/51V
Earth fault, sensitive earth fault
50N/51N 50G/51G
4
4
4
4
4
4
4
4 1
DE40548
8 types of Sepam series 40
1
Breaker failure
50BF
1
1
1
1
1
1
1
Unbalance/negative sequence
46
2
2
2
2
2
2
2
Directional phase overcurrent
67
Directional earth fault
67N/67NC
2
2
2
Directional real overpower
32P
1
1
1
Directional reactive overpower
32Q/40
Thermal overload
49 RMS
Phase undercurrent
37
2
2 2
2
2
2 1
1
1
1
2
2
1
Locked rotor, excessive starting time 48/51LR/14
1
Starts per hour
66
1
Positive sequence undervoltage
27D
2
Remanent undervoltage
27R
Undervoltage
27/27S
2
2
2
2
2
2
2
Overvoltage
59
2
2
2
2
2
2
2
Neutral voltage displacement
59N
2
2
2
2
2
2
2
Negative sequence overvoltage
47
1
1
1
1
1
1
1
Overfrequency
81H
2
2
2
2
2
2
2
Underfrequency
81L
4
4
4
4
4
4
4
Recloser (4 cycles)
79
v
v
v
Temperature monitoring) (8 or 16 RTDs, 2 set points per RTD
38/49T
v
v
v
v
Thermostat / Buchholz
26/63
v
v
1
v
Metering RMS phase current I1,I2,I3, residual current I0
b
b
b
b
b
b
b
b
Average current I1, I2, I3 Peak demand current IM1, IM2, IM3
b
b
b
b
b
b
b
b
Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0
b
b
b
b
b
b
b
b
Positive sequence voltage Vd/rotation direction, Negative sequence voltage Vi
b
b
b
b
b
b
b
b
Frequency
b
b
b
b
b
b
b
b
Real / reactive / apparent power P, Q, S Peak demand real/reactive power PM, QM Power factor
b
b
b
b
b
b
b
b
Calculated real / reactive energy (±W.h, ±var.h)
b
b
b
b
b
b
b
b
Real/reactive energy impulse counter (±W.h, ±var.h) v
v
v
v
v
v
v
v
v
v
v
v
Temperature Tripping current TripI1, TripI2, TripI3, TripI0
b
b
b
b
b
b
b
b
Tripping context
b
b
b
b
b
b
b
b
Unbalance ratio/negative sequence current
b
b
b
b
b
b
b
b
Phase shift φ0, φ1, φ2, φ3
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Thermal capacity used
b
b
b
b
Remaining operating time before overload tripping
b
b
b
b
Waiting time after overload tripping
b
b
b
b
Running hours counter / operating time
b
b
b
b
Disturbance recording
Starting current and time
b
Start inhibit time delay, number of starts before inhibition
b
Switchgear diagnosis Cumulative breaking current
b
b
b
b
b
b
b
b
Trip circuit supervision
v
v
v
v
v
v
v
v
Number of operations, operating time, charging time v
v
v
v
v
v
v
v
b
b
b
b
b
b
b
b b
CT/VT supervision
Control and monitoring
ANSI code
Circuit breaker / contactor control
94/69
b
b
b
b
b
b
b
Latching / acknowledgment
86
b
b
b
b
b
b
b
b
Logic discrimination
68
v
v
v
v
v
v
v
v
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Measurement readout
v
v
v
v
v
v
v
v
Remote indication and time tagging of event
v
v
v
v
v
v
v
v
Remote control orders
v
v
v
v
v
v
v
v
Remote setting of protections
v
v
v
v
v
v
v
v
Transfer of disturbance recording data
v
v
v
v
v
v
v
v
Switching of group of settings Annunciation
30
Logical equation editor
Communication port
b standard, v according to parameter settings and optional modules. Note: the figures (in the table) give the number of independant protection sets for each protection function.
Schneider Electric Industries SAS 89, boulevard Franklin Roosevelt F-92505 Rueil-Malmaison Cedex Tél. : +33 (0)1 41 29 85 00 www.schneider-electric.com
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Printed on recycled paper. Publication: Schneider Electric Industries SAS Design: Schneider Electric Industries SAS Print :
ART.07900
12/2008
PCRED301002EN/7 © 2008 Schneider Electric Industries - All rights reserved
Network and machine diagnosis